− 66 −
. . . Item that is not displayed due to other setting state.
No. Item
Setting range
/
Edit unit
Initial value
Stacker timer 3
Motion time of material sweeping bar is set.
*
It is possible to set only when clamp bar stacker option is
used.
0.00 to
9.99
/
0.01 sec.
0.70 sec.
Stacker timer 4
Time to advance timing to release the sewing product by lifting clamp
foot is set.
When clamping a short sewing product, the amount to drop by tare is
adjusted.
*
It is possible to set only when clamp bar stacker option is
used.
0.00 to
9.99
/
0.01 sec.
0.00 sec.
Sewing speed under the high-speed mode
Number of revolutions of lockstitch section is set.
*
It is possible to set only when
sewing speed setting
selection is set to memory switch.
1000 to
3000
/
100
sti/min
2500sti/min
Sewing speed under the low-speed mode
Number of revolutions of condensation and back tack sewing sections
is set.
*
It is limited by sewing speed under the high-speed mode.
*
It is possible to set only when sewing speed setting
selection is set to memory switch.
1000 to
2500
/
100
sti/min
1500sti/min
Soft start, rst stitch
Number of revolutions of rst stitch at sewing start is limited.
500 to
2500
/
100
sti/min
500sti/min
Soft start, second stitch
Number of revolutions of second stitch at sewing start is limited.
500 to
2500
/
100
sti/min
700sti/min
Soft start, third stitch
Number of revolutions of third stitch at sewing start is limited.
500 to
2500
/
100
sti/min
1000sti/min
Return speed of clamp foot
Return speed of clamp foot is set.
3 to 9
/
1
7
Thread breakage detection
With/without thread breakage detection is selected.
- - -
With thread
breakage detection
Without thread
breakage detection
Flap presser motion mode
Motion order of ap presser is selected.
From right From left
Right/Left at the
same time
Side where ap is
put
*
When right and left are simultaneously actuated with customizing of
pedal setting, this parameter is neglected and the right and left are
simultaneously actuated.