− 65 −
(2) Memory switch data list
1
Level 1
Memory switch data (level 1) are the motion data that the sewing machine has in common and the data
that operate on all sewing patterns in common.
. . . Item that is not displayed due to other setting state.
No. Item
Setting range
/
Edit unit
Initial value
Change-over of the position of clamp foot after sewing end
Position of clamp foot after sewing end is selected from Stop at front
end/Return to medium/Clamp return/Stop at rear end.
- - -
Stop at front end Return to medium
Clamp return Stop at rear end
Front end motion start waiting time
Waiting time up to the start of front end motion of clamp foot is set.
*
It is possible to set only when is set to the stop at front end.
0.50 to
9.99
/
0.01 sec.
3.00 sec.
Number of times of feeding of automatic interlining supplying at
sewing start
Number of times of feeding of automatic interlining supplying device at
sewing start is set.
*
It is possible to set only when automatic interlining
supplying option is used.
2 to 9
/
1
3
Feeding length of automatic interlining supplying at sewing end
Feeding length of automatic interlining supplying device at sewing end
is set.
*
It is possible to set only when
automatic interlining supplying
device is used.
0 to 99.9
/
0.1mm
0mm
Thread trimming timing
Thread trimming timing after sewing is selected from Standard/
Medium/Longest and length of thread at sewing end is adjusted.
- - -
Standard 0 Medium 1
Longest 2
*
When
Ready-made zipper device is mounted and the setting is set
to standard value "0", needle thread may not be cut.
Stacker timer 2
Waiting time from the start of clamp motion to hold material on the
stacker base to release the material presser is set.
*
It is possible to set only when
clamp bar stacker option is
used.
0.00 to
9.99
/
0.01 sec.
0.70 sec.