– 88 –
No. Item Setting range Unit
U039
Start position of rotation
Set start position from neutral pedal potision. (Pedal Stroke)
10 to 1000
U040
Start position of acceleration
Set accelerating position from neutral pedal position. (Pedal Stroke)
10 to 1000
U041
Start position of lifting of presser foot
Set work clamp lift position from neutral pedal position. (Pedal Stroke)
-500 to -10
U042
Start position of lowering of presser foot
Set work clamp fall position from neutral pedal position. (Pedal Stroke)
10 to 500
U043
Start position of thread trimming
Set thread triming starting position from neutral pedal position. (Pedal Stroke)
-1000 to -100
U044
Position that maximum sewing speed is reached
Set maximum speed reaching position from neutral pedal position. (Pedal Stroke)
10 to 15000
U045
Pedal neutral-position correction value
Set neutral position of pedal sensor.
-150 to 150
U047
Presser-foot lift nishing position
The position to which the presser foot goes up when the back part of the pedal is
depressed to its rst step. (1st-step spring position)
-1000 to -100
U048
Function of lifting the presser foot by depressing the pedal
Whether or not the presser-foot lifting operation is carried out by depressing the
back part of pedal is set.
0: No operation / 1: Operation
0 to 1
U049
Presser foot lowering time
Time to lower the presser foot is set.
0 to 500 ms
U051
Correction of turning-ON of reverse feed stitching (at start)
-50 to 50 Degree
U052
Correction of turning-OFF of reverse feed stitching (at start)
-50 to 50 Degree
U053
Correction of turning-OFF of reverse feed stitching (at end)
-50 to 50 Degree
U054
Standby time until the presser foot starts going up
Time to be elapsed from the moment the pedal is depressed to the 1st step to the
moment the presser foot starts going up.
0 to 200 ms
U056
Reverse-rotation needle-up after thread trimming
The initial value di󰀨ers with the machine head.
0: Reverse-rotation needle-up is not performed / 1: Reverse-rotation needle-up is
performed
0 to 1
U058
Needle bar home position retaining function
The retaining function retains the needle bar at upper or lower stop position. The
initial value varies with the machine head.
0: Disabled / 1: Enabled; Weak retaining force / 2: Enabled; Medium retaining force
/ 3: Enabled; Strong retaining force
0 to 3
U059
Selection of revere feed stitching (at start) operation
0: By manually operating the pedal, etc. / 1: According to the preset reverse feed
sewing speed
0 to 1
U060
Stop after reverse feed stitching (at start)
The stop function stops the sewing machine temporarily regardless of the operat-
ing status of the pedal.
0: OFF / 1: ON
0 to 1
U064
Sewing speed at the start of reverse feed stitching (at end)
150 to 1000 sti/min