– 93 –
Error
code
Description of error Cause Item to be checked
E205 ISS bu󰀨er capacity
runout warning
Bu󰀨er for storing ISS data will soon be
lled to its capacity.
If the bu󰀨er is used continuously, the
stored data will be automatically erased
on FIFO basis.
Output the ISS data.
E220 Warning against short-
age of grease
When the predetermined number of
stitches is reached.
Add grease to the specied points of
sewing machine and reset the error.
E221 Grease-shortage error In the case the sewing machine cannot
continue sewing since the predeter-
mined number of stitches is reached.
Add grease to the specied points of
sewing machine and reset the error.
E302 Head-tilt detection error
(When the safety switch
operates)
In the case the Tilt detection switch is
turned ON when the power to the sew-
ing machine remains ON.
Check whether the machine head is
tilted before turning OFF the power
switch (The sewing machine oper-
ation is prohibited for the sake of
safety.)
E303 Meniscus sensor error In the case the meniscus sensor signal
cannot be detected.
Check for a break in the motor en-
coder connector.
E402 Deletion disabled error In the case of attempting to delete the
pattern which is used in a cycle pattern.
In the case of attempting to delete the
custom pitch or condensation custom
which is used in a pattern.
E407 Wrong password In the case the password entered is
wrong.
E408 Shortage of number of
password characters
In the case the number of password
characters entered is not enough.
E411 Polygonal stitching pat-
tern registration disabled
error
In the case of attempting to create elev-
en or more polygonal stitching patterns.
E412 Custom pitch unregis-
tered error
In the case the custom pitch number is
faulty.
E413 Condensation custom
unregistered error
In the case the condensation custom
number is faulty.
E499 Simplied program fault
E704 Data failure (system-ver-
sion mismatch)
In the case the system version does not
match the machine head setting.
Re-write the system version to the
applicable one.
E731 Motor hole sensor fault In the case the motor signal is not input
properly.
Check whether the motor signal con-
nector has loosened or slipped o󰀨.
Check whether the motor signal cord
has broken by being caught under
the machine head.
Check whether the insertion direction
of the motor encoder connector is
correct.
E733 Reverse rotation of
motor
When the motor runs at a speed of 500
sti/min. or more, the motor runs in the
reverse direction of the indicated direc-
tion of rotation.
Check whether the main shaft motor
encoder wire connection is correct.
Check whether the main shaft motor
wire connection for power is correct.
E750 Sewing machine stops In the case the optional-input safety
switch is pressed.