CHAPTER 13
Installing the Rack Mounting Hardware
•
Preparing the SRX320 Services Gateway for Rack-Mount Installation on page 49
•
Preparing the SRX320 Services Gateway for Wall-Mount Installation on page 50
•
Preparing the SRX320 Services Gateway for Desk-Mount Installation on page 50
•
Connecting the SRX320 Services Gateway to the Building Structure on page 51
Preparing the SRX320 Services Gateway for Rack-Mount Installation
You can mount an SRX320 Services Gateway in four-post (telco) racks, enclosed cabinets,
and open-frame racks.
NOTE: The SRX320 Services Gateway cannot be center-mounted in racks.
Before mounting the SRX320 Services Gateway in a rack:
•
Verify that the installation site meets the requirements described in “Site Preparation
Checklist for the SRX320 Services Gateway” on page 20.
•
Verify that the racks or cabinets meet the specific requirements described in “SRX320
Services Gateway Rack-Mounting Requirements and Warnings” on page 25.
•
Place the rack or cabinet in its permanent location, allowing adequate clearance for
airflow and maintenance, and secure it to the building structure. For more information,
see “SRX320 Services Gateway Clearance Requirements for Airflow and Hardware
Maintenance” on page 30.
•
Remove the services gateway chassis from the shipping carton. For unpacking
instructions, see “Unpacking the SRX320 Services Gateway” on page 45.
•
Verify that you have the following parts available in your rack-mounting kit:
•
Rack-mount tray
•
Screws
NOTE: The rack-mounting kit is not shipped with the device and must be
ordered separately.
49Copyright © 2016, Juniper Networks, Inc.