102 English 5.906-432.0 Rev. 00 (06/15)
7.30 Testing the water temperature setting and the programme switch
Display Explanation Remark
55°C Output image for temperature selector switch test. Use SET to access the tem-
perature selector switch test.
Temperaturwahlschaltertest. Es wird die am Tem-
peraturwahlschalter gewählte Temperatur an-
gezeigt.
Wenn der Temperaturwahls-
chaltertest fertig ist, muss
wieder 55°C gewählt
werden. Mit SET gelangt
man in den Hauptschaltert-
est
Main switch test
Main switch test
Main switch test
Main switch test This display appears only
very briefly as the device is
also switched off here.
7.31 Test service switch
Display Explanation Remark
60°C Selected liquid softener setting.