3 Technical Data
Unless otherwise indicated, all electrical data in the following chapter refer to a 3-phase
AC voltage supply.
3.1 Operating conditions
3.1.1 Climatic environmental conditions
Storage Standard Class Descriptions
Ambient temperature EN 60721-3-1 1K4 -25…55°C
Relative humidity EN 60721-3-1 1K3 5…95 % (without condensation)
Storage height Max. 3000 m above sea level
Transport Standard Class Descriptions
Ambient temperature EN 60721-3-2 2K3 -25…70°C
Relative humidity EN 60721-3-2 2K3 95%at40°C(withoutcondensation)
Operation Standard Class Descriptions
Ambient temperature EN 60721-3-3 3K3 5…40°C(extendedto-10…45°C)
Coolant inlet temperature 5…40°C(-10…45°C)
Relative humidity EN 60721-3-3 3K3 5…85 % (without condensation)
Version and degree of protec-
tion
EN 60529 IP20
Protection against foreign material > ø12.5 mm
No protection against water
Non-conductive pollution, occasional conden-
sation when PDS is out of service.
Site altitude
Max. 2000 m above sea level
With site altitudes over 1000 m a derating
of 1 % per 100 m must be taken into con-
sideration.
With site altitudes over 2000 m, the control
board to the mains has only basic isola-
tion. Additional measures must be taken
when wiring the control.
Table 3: Climatic environmental conditions
27
OPERATING CONDITIONS

Table of Contents

Other manuals for KEB COMBIVERT S6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT S6 Series and is the answer not in the manual?

KEB COMBIVERT S6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT S6 Series
CategoryController
LanguageEnglish

Related product manuals