Frequency-dependent maximum current 400 V devices
Device size
07
Rated switching frequency
8 kHz
Output frequency f
out
/ Hz
0 3.1 6.2 12.5 25 50
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
Iout_max / %
4 kHz 215
300 300
300
300
300
8 kHz 162
238 292
300
300
300
16 kHz 92
158 200
235
265
292
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
Iout_max / %
7 kHz 175
254 300
300
300
300
14 kHz 104
175 215
252
287
300
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
Iout_max / %
6 kHz 188
269 300
300
300
300
12 kHz 115
192 231
269
308
346
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
Iout_max / %
5 kHz 202
285 300
300
300
300
10 kHz 138
215 262
300
300
300
Table 24: Frequency-dependent maximum current for device size 07 400 V devices
Device size
09
Rated switching frequency
8 kHz
Output frequency f
out
/ Hz
0 3.1 6.2 12.5 25 50
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
Iout_max / %
4 kHz 193
266 300
300
300
300
8 kHz 132
198 234
256
283
300
16 kHz 73
122 146
166
183
200
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
Iout_max / %
7 kHz 147
215 253
276
300
300
14 kHz 85
138 159
180
201
216
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
Iout_max / %
6 kHz 162
232 272
296
300
300
12 kHz 98
154 171
195
220
232
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
Iout_max / %
5 kHz 177
249 291
300
300
300
10 kHz 115
176 202
226
251
267
Table 25: Frequency-dependent maximum current for device size 09 400 V devices
Device size
10
Rated switching frequency
8 kHz
Output frequency f
out
/ Hz
0 3.1 6.2 12.5 25 50
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
Iout_max / %
4 kHz 155
250 284
300
300
300
8 kHz 103
172 207
233
255
276
16 kHz 50
103 121
138
155
164
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
Iout_max / %
7 kHz 116
192 226
254
278
297
14 kHz 64
116 138
155
177
185
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
Iout_max / %
6 kHz 129
211 246
276
300
300
12 kHz 78
129 155
172
198
207
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
Iout_max / %
5 kHz 142
231 265
297
300
300
10 kHz 91
151 181
203
227
241
Table 26: Frequency-dependent maximum current for device size 10 400 V devices
44
GENERAL DATA

Table of Contents

Other manuals for KEB COMBIVERT S6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT S6 Series and is the answer not in the manual?

KEB COMBIVERT S6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT S6 Series
CategoryController
LanguageEnglish

Related product manuals