50 Disassembly and assembly SEN04134-00
PC130-8
3
Removal and installation of air
conditioner condenser 1
Removal
k Disconnect the negative terminal (–) of the
battery before starting the work.
k Collect the air conditioner refrigerant
(R134a) from air conditioner circuit in
advance.
a Ask professional traders for collecting and fill-
ing operation of refrigerant (R134a).
a Never release the refrigerant (R134a) to the
atmosphere.
k If refrigerant gas (R134a) gets in your eyes,
you may lose your sight. Accordingly, put
on protective goggles while you are collect-
ing the refrigerant (R134a) or filling the air
conditioner circuit with the refrigerant
(R134a). Collecting and filling work must be
conducted by a qualified person.
1. Disconnect wiring connectors (1) and (2).
2. Remove radiator reservoir tank (3).
3. Remove air cleaner assembly (4).
4. Remove bracket (5).
5. Disconnect 2 hoses (6).
a Stop the hoses and condenser with blind
plugs to prevent water etc. will not enter
them.
6. Remove bolts (7) (2 pieces each on the right
and left sides) and remove condenser assem-
bly (8). [*1]
Installation
q Carry out installation in the reverse order to
removal.
[*1]
3 Mounting bolt: Adhesive (LT-2)
3 Mounting bolt:
10.0 – 15.0 Nm {1.0 – 1.5 kgm}
q Charging air conditioner with refrigerant
Charge the air conditioner circuit with refriger-
ant (air conditioner gas R134a).
a Filling quantity: 850 ± 50 g