40 Troubleshooting SEN04119-01
PC130-8
3
Failure code [989L00] Engine controller lock caution 1 1
Failure code [989M00] Engine controller lock caution 2 1
User code Failure code
Trouble
Engine controller lock caution 1
(Machine monitor system)
— 989L00
Contents of
trouble
• Engine controller lock is detected (Factor 1).
Action of
machine monitor
• None in particular.
• If cause of failure disappears, system resets itself.
Problem that
appears on
machine
• Engine cannot be started.
Related
information
• If this failure code is displayed after machine monitor is replaced, user password must be changed
to one before replacement.
• Method of reproducing failure code: Turn starting switch ON.
Possible causes
and standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
1
Replacement of machine
monitor
This trouble may be caused by replacement of machine monitor.
User code Failure code
Trouble
Engine controller lock caution 2
(Machine monitor system)
— 989M00
Contents of
trouble
• Engine controller lock is detected (Factor 2).
Action of
machine monitor
• None in particular.
• If cause of failure disappears, system resets itself.
Problem that
appears on
machine
• Engine cannot be started.
Related
information
• If this failure code is displayed after machine monitor is replaced, user password must be changed
to one before replacement.
• Method of reproducing failure code: Turn starting switch ON.
Possible causes
and standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
1
Replacement of machine
monitor
This trouble may be caused by replacement of machine monitor.
2 Defective machine monitor
If this failure code is displayed while machine monitor is not
replaced, machine monitor may be defective. (Since trouble is in
system, troubleshooting cannot be carried out.)