SEN04121-02 40 Troubleshooting
34 PC130-8
Failure code [DW91KB] Travel junction sol short 1
User code Failure code
Trouble
Travel junction solenoid system shortï€
(Pump controller system)
— DW91KB
Contents of
troubl
e
• When output to travel junction solenoid was turned ON, short circuit was detected in circuit.
Action of
control
ler
• Turns output to travel junction solenoid OFF.
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
a
ppears on
machine
• Machine is not steered easily during travel.
Related
information
• Operating condition of travel junction solenoid
can be checked with monitoring function. ï€
(Code: 02300 Solenoid 1)
• Method of reproducing failure code: S
tart engine + Steer machine with right and left travel levers.
Possible causes
and
standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
1
Defective travel junction
solenoid (Internal short cir-
cuit or ground fault)
a Prep
are with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
V03 (male) Resistance
Between (1) – (2) 20 – 60 z
Between (2) – chassis ground Min. 1 Mz
2
Ground fault in wiring har-
ness (Short circuit with GND
circuit)
a Prep
are with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between CP02 (female)
(1
10) – V03 (female) (2) and chassis ground
Resis-
tance
Min. 1 Mz
3 Defective pump controller
a Prep
are with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
CP02 (female) Resistance
Between (110) – (115), (117),
(120)
20 – 60 z
Between (110) – chassis ground Min. 1 Mz