OPERATION
OPERATION
CHECK WATER SEPARATOR, DRAIN WATER AND SEDIMENT
1.
Open the side cover on the left side of the machine.
The water separator and pre-fuel filter form one unit and are at
the bottom.
2.
It is possible to judge the water level and amount of sediment
by looking through transparent cap (2). If there is any water or
sediment collected at the bottom, set a container to catch the
drain water under drain hose (3).
3. Loosen plug (1) and drain the water.
4.
When fuel comes out from drain hose (3), tighten plug (1)
immediately.
Tightening torque: 0.2 to 0.45 Nm (0.02 to 0.046 kgm, 0.1 to 0.3
lbft)