89APPENDIX
APPENDIX
SERVICE HOUR METER
When the hour meter has counted up to the hours circled in the maintenance list below, the message appears. The
message shows up as follows.
The maintenance message appears. The message shows up as shown right.
(The maintenance message reappears on the hour meter designated next.)
A The maintenance (periodic check) message can be automatically disappeared.
C In case the service hour meter replaced due to any trouble with it, the meter is set to "0". Contact your KUBOTA dealer
for details.
No. Check points Measures
Hour meter indicator
Intervals
50 100 250 500 600 750 1000
1 Engine oil
change
every 250 hrs
2 Hydraulic oil every 1000 hrs
3
Air cleaner
element
Outer element
replace
every 1000 hrs
Inner element every 1000 hrs
4 Fuel filter cartridge
replace
every 500 hrs
5 Engine oil filter every 250 hrs
6 Front/rear axle oil change every 1000 hrs
7 Hydraulic return filter
replace
every 500 hrs
8 Hydraulic suction filter every 1000 hrs
9 HST oil filter every 1000 hrs

Table of Contents