Page #93 background imageLoading...
Page #93 background image
65PERIODIC SERVICE
BCleaning evacuator valve
Open the evacuator valve to get rid of large particles of
dust and dirt.
BChecking dust indicator
There is a dust indicator on the air cleaner body. If the red
signal on the dust indicator is visible, clean the element
immediately. (See "Cleaning and checking air cleaner
element" in "EVERY 250 HOURS SERVICE" in
"PERIODIC SERVICE" section.) Reset the red signal by
pushing a "RESET" button after cleaning.
BChecking washer liquid [CABIN TYPE
ONLY]
If the windows washer is switched on with the washer
liquid tank empty, the motor may be damaged. Always
keep the tank filled.
A Get the washer liquid tank half filled (about 0.8 liter)
before working on a slope or a rough ground. The
liquid may leak out when the machine bounces.
BCleaning Pre-Cleaner
To clean the pre-cleaner, remove the wing nut and
remove the pre-cleaner bowl.
(1) Evacuator valve
(1) "RESET" button
(2) Dust indicator
(3) Red signal
(1) Washer liquid tank
(1) Wing nut
(2) Pre-cleaner bowl
(A) "DUST LEVEL"

Table of Contents