2-35
The main unit setup procedure > Installation
[CONFIDENTIAL]
(9-1) Store the protective caps for shipping
Cleaning the protective caps for shipping
1
Fold the Alpha wiper [A] and drop a little deionized water [B] (2ml) on it.
2
Wipe 12 caps (silicon sheet) [A] with the Alpha wiper [B].
Wipe them in the same direction until the ink is removed.
Pay attention that the Alpha wiper does not touch on the frame edge.
And do not let the Teflon sheet or the sponge on the cap deform.
3
Wipe deionized water on the cap with dried part of the Alpha wiper and check if no
dirt on the caps.
Wear rubber gloves in handling. (If the liquid get your hands, rinse it immediately with water.)
[A]
[B]
How to fold
[A]
[B]