COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Fits and Clearances
23–70–30
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Rev. 02 Page 804
July 21/17
Table 801. Model FA5000 Environmental Characteristics
The Model FA5000 recorders will be tested to DO−160F categories listed below.
DO-160F Section
DO-160F Section
Number
DO-160F Category Compliance (Not
including RIPS battery)
Temperature and Altitude 4 D2/F3
Temperature Variation 5 A
Humidity 6 B
Shock 7 B
Vibration 8 R Curve E & E1/H Curve P
Explosion Atmosphere 9 E, H Env II
Water Proofness 10 Y/W
Fluid Susceptibility 11 F
Sand and Dust 12 D
Fungus Resistance 13 F
Salt Fog 14 S
Magnetic Effect 15 A
Power Input 16 DC: ZXX;
Voltage Spike 17 A
Conducted Susceptibility 18 DC: Z
Induced Signal Susceptibility 19 ZC
RF Radiated and Conducted
Susceptibility
20 RR
RF Radiated and Conducted
Emissions
21 H , L
Lightning Induced Transient
Susceptibility
22 A3J44
Lightning Direct Effects 23 X
Icing 24 A
Electro Static Discharge
(ESD)
25 A
Fire, Flammability 26 B
The document reference is online, please check the correspondence between the online documentation and the printed version.