results. If an audio input circuit failure occurs after a successful PushtoTest oper-
ation, it will not be detected, or reported, until the next PushtoTest is initiated.
This audio input circuit failure is the only fault that would not otherwise be detected
and reported by the CVR continuous BITE. PushtoTest results are reported, dur-
ing the test, using the CVR Test Indicator output (Pins 15/16) which is usually con-
nected to an indicator lamp or meter on the CVR Control Unit. In addition, CVR fail-
ures reported through the PushtoTest operation will be indicated by muting of the
CVR Monitor Audio output (Pins 5/6).
The fault criteria used to determine the reporting status associated with the CVR La-
bel 350 Status Word bits are summarized in Table 1.5.
Table 8. CVR STATUS WORD FAULT REPORTING CRITERIA
L350
BIT
FUNCTION FAILURE CRITERIA
11 CVR Status (Audio Record-
ing Failure)
Any internal CVR failure that prevents correct record-
ing of the audio inputs (including CU failure and
PushtoTest audio input circuit failure). May relent
depending on fault severity.
12 CMC Bus Status (OMS In-
put)
Loss of OMS input Heartbeat (valid Label 227 input)
for more than 3 seconds. Relents if OMS Heartbeat is
restored.
13 CVR Control Unit Failure Loss of 18 VDC Control Unit supply voltage. Relents if
voltage level returns.
14 FDR Status (not used) Always reported as “Failed” in CVR only recorder.
15 RIPS Fault Status (Pin 29) RIPS Fault as reported on pin 29 input (if present).
16 CVR DataLink Recording
Failure
Any internal CVR failure that prevents correct record-
ing of the DataLink input.
17 Clock Status Loss of the ARINC 429 GMT input (Label 125 or 150)
for more than 40 seconds. Relents if clock input is
restored.
18 Data Link Input Interface Loss of the DataLink Heartbeat (valid Label 270) for
more than 3 seconds (only if DataLink Valid, Pin 56, is
asserted). Relents if DataLink Heartbeat is restored
or DataLink Valid removed.
Or
Presence of DataLink Heartbeat (valid Label 270) if
DataLink Valid, Pin 56, is not asserted. Relents if
DataLink Valid is asserted or DataLink Heartbeat is
removed.
19 CVR Record Enable
(Pins 7/8)
CVR “Record Enable” jumper status (pins 7/8).
The document reference is online, please check the correspondence between the online documentation and the printed version.

Table of Contents

Other manuals for L3 FA5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the L3 FA5000 and is the answer not in the manual?

L3 FA5000 Specifications

General IconGeneral
BrandL3
ModelFA5000
CategoryVoice Recorder
LanguageEnglish

Related product manuals