9: Device Ports
SLCâ„¢ 8000 Advanced Console Manager User Guide 191
Host Parameters
4. Click the right arrow. The host displays in the Hosts box.
5. Repeat steps 2-4 to add more hosts to the host list.
6. Click the Clear Host Parameters button to clear fields before adding the next host.
7. You have the following options:
- To remove a host from the host list, select the host in the Hosts box and click the
left arrow.
- To give the host a higher precedence, select the host in the Hosts box and click the
up arrow.
- To give the host a lower precedence, select the host in the Hosts box and click the
down arrow.
8. Click the Add Host List button. After the process completes, a link back to the Device Ports >
Settings (1 of 2) page displays.
Host Name or IP address of the host.
Protocol Protocol for connecting to the host (TCP, SSH, or Telnet).
Port Port on the host to connect to.
Escape Sequence The escape character used to get the attention of the SSH or Telnet client. It is
optional, and if not specified, Telnet and SSH use their default escape character.
For Telnet, the escape character is either a single character or a two-character
sequence consisting of '^' followed by one character. If the second character is '?',
the DEL character is selected. Otherwise, the second character is converted to a
control character and used as the escape character.
For SSH, the escape character is a single character.
Note: When the Device Port Esc Sequence/ViewLog/PowerMenu Escape
Sequence is configured, the following escape sequence precedent behavior can be
expected: 1) Escape 2) PowerMenu 3) ViewLogs
A clear/restart of the remaining escape events occurs when there is a match in any
configured sequence. All the sequences should have unique sequence defined and
user should avoid overlapping sequence strings. When detecting key sequences,
after receiving the first character(s) of a sequence, the SLC will wait 3 or more
seconds for the remaining characters, before timing out and sending all characters
to the device. For example, if the Escape Sequence is ABCD, and the user types
"AB", the SLC will wait at least 3 seconds for the next character ("C") before timing
out and sending the "AB" characters to the device.