7: 59BSetup Mode: Channel Configuration
XPort® Device Server User Guide 50
Table 7-3. Interface Mode Options
I/F Mode Option
7
6
5
4
3
2
1
0
RS-422 4-wire
0
1
RS-485 2-wire
1
1
Flow
Flow control sets the local handshaking method for stopping serial input/output.
Flow (0) ? _
Use the following table to select flow control options:
Table 7-4. Flow Control Options
Flow Control Option
Hex
No flow control
00
XON/XOFF flow control
01
Hardware handshake with RTS/CTS lines
02
XON/XOFF pass characters to host
05
Port Number
The setting represents the source port number in TCP connections. It is the number that
identifies the channel for remote initiating connections.
Port No (10001) ? _
The default setting for Port 1 is 10001. The range is 1-65535, except for the following
reserved port numbers:
Table 7-5. Reserved Port Numbers
Port Numbers
Reserved for
1 1024
Reserved (well known ports)
9999
Telnet setup
14000-14009
Reserved for Redirector
30704
Reserved (77F0h)
30718
Reserved (77FEh)
WARNING: We recommend that you not use the reserved port numbers for this
setting as incorrect operation may result.
Use Port 0 for the outgoing local port to change with each connection. The port range is
50,000 to 59,999. Each subsequent connection increments the number by 1 (it wraps back
around to 50,000).

Table of Contents

Other manuals for Lantronix XPort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix XPort and is the answer not in the manual?

Lantronix XPort Specifications

General IconGeneral
BrandLantronix
ModelXPort
CategoryServer
LanguageEnglish

Related product manuals