XPort® Device Server User Guide 89
Problem/Message Reason Solution
The device server appears to
be set up correctly, but you are
not communicating with your
device attached to the device
server across the network.
If you are sure that the serial
port setting is correct, then you
may not be connecting to the
correct socket of the device
server.
Another possibility is that the
device server is not set up
correctly to make a good socket
connection to the network.
You can check to see whether
there is a socket connection to
or from the device server by
checking the state of CP1, if it
has been configured for LED1
functionality.
If the state of CP1 is blinking
consistently, or is completely
off, then there is a good socket
connection.
If the state of CP1 is low, use
the Connect Mode option C0 for
making a connection to the
device server from the network.
Use Connect Mode option C1
or C5 for a connection to the
network from the device server.
See the full list of Connect
Mode options in Connect Mode.
When connecting to the Web
Manager within the device
server, the "No Connection With
The Device Server" message
displays.
Your computer is not able to
connect to port 30718 (77FEh)
on the device server.
Make sure that port 30718
(77FEh) is not blocked with any
router that you are using on the
network. Also, make sure that
port 77FEh is not disabled
within the Security settings of
the device server.

Table of Contents

Other manuals for Lantronix XPort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix XPort and is the answer not in the manual?

Lantronix XPort Specifications

General IconGeneral
BrandLantronix
ModelXPort
CategoryServer
LanguageEnglish

Related product manuals