Manitowoc Published 09-05-14, Control # 226-02 3-13
14000 SERVICE MANUAL ELECTRIC SYSTEM
36-S 24 Volts
Remote Control - Power 24 Volts Nominal
36-T 24 Volts
Drum 1 Free Fall Pressure Sender A 24 Volts Nominal
36-U Ground
Drum 1 Free Fall Pressure Sender A Ground
36-W Ground
Drum 2 Free Fall Pressure Sender B Ground
36-X
24 Volts Drum 2 Flange Encoder 24 Volts Nominal
36-Z Ground
Drum 2 Flange Encoder Ground
36-a AI-9
Drum 1 Free Fall Pressure Sender A 0 Volts Off; 24 Volts On CAN6-2-16
36-b AI-10
Drum 2 Free Fall Pressure Sender B 0 Volts Off; 24 Volts On CAN6-2-128
36-c AI-11
Remote Control - Gantry Cylinders - Raise 0 Volts Off; 24 Volts On CAN6-2-64
36-e AI-13
Remote Control - Emergency Stop 0 Volts Off; 24 Volts On CAN7-2-16
36-d AI-12
Remote Control - Gantry Cylinders - Lower 0 Volts Off; 24 Volts On CAN6-2-128
36-g 24 Volts
Drum 2 Free Fall Pressure Sender B 24 Volts Nominal
36-j Ground
Drum 1 Flange Encoder Ground
36-m 24 Volts
Drum 1 Flange Encoder 24 Volts Nominal
36-n EC1A
Drum 1 Flange Encoder
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN37-1
2
36-p EC1B
Drum 1 Flange Encoder
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN37-1
2
36-r EC-2A
Drum 2 Flange Encoder
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN-37-3
2
36-s EC-2B
Drum 2 Flange Encoder
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN37-3
2
2
The number in the indicated bank should increase with device rotation and decrease with rotation in opposite direction.