Manitowoc Published 09-05-14, Control # 226-02 3-19
14000 SERVICE MANUAL ELECTRIC SYSTEM
3
Luffing Jib Remote Input Node
See Electrical Schematic A17144, Sheet 12 (at end of this section).
Receptacle/
RIN ID
Wire No. Description Test Voltage
J1 Receptacle – Input/Output
311A P1A System Power 12 Volts Nominal
311B P1B Data Out Variable 0 to 12 Volts
311C P1C System Ground Ground
J2 Receptacle – Input/Output to Wind Speed RIN
312A P5A System Power 12 Volts Nominal
312B P5B Data In Variable 0 to 12 Volts
312C P5C System Ground Ground
J3 Receptacle – Boom Items
313G P6WT Block-Up Limit 4 0 Volts Off; 12 Volts On
313E P6BK Block-Up Limit 4 CAN-85-2-128
313N P9WT Block-Up Limit 3 0 Volts Off; 12 Volts On
313H P9BK Block-Up Limit 3 CAN-85-2-64
313J P7BN Load Sensor 3 12 Volt Nominal
313D P7WT Load Sensor 3 AC 2
313F P7BK Load Sensor 3 Ground
313R P8BN Load Sensor 4 12 Volts Nominal
313M P8WT Load Sensor 4 AC 1
313S P8BK Load Sensor 4 Ground
P Receptacle – Angle Sensor
P10 P10 Jib Angle Sensor Ground
P11 P11 Jib Angle Sensor AR 1
P12 P12 Jib Angle Sensor 5 Volts Nominal

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals