Manitowoc Published 09-05-14, Control # 226-02 3-33
14000 SERVICE MANUAL ELECTRIC SYSTEM
Remote Control Functions
Select remote control functions from screen below
Multiple Points or Load Pin
Disable Functions
Select multiple points or load pin disable functions from
screen below.
Swing or Track Speed Limits
See Figure 3-24 in following procedure.
Swing and crawler speeds can be selected. In level 3, the
value shown in these data boxes can be adjusted with Select
buttons to limit the function speed between 25% and 100%
of maximum capability.
Remote Control
FIGURE 3-22
14COM3-45
Multiple Points
Load Pin Disable
FIGURE 3-23
14COM3-90
FIGURE 3-24
Swing Speed Limits
14COM3-46b
Crawler Speed Limits