Page #214 background imageLoading...
Page #214 background image
Reference Only
POWER TRAIN 14000 SERVICE MANUAL
7-2
Published 09-05-14, Control # 226-02
Overloads
Avoid prolonged cranking or the addition of extra electric
devices which will drain the battery and may cause
excessive heat.
Multiple Battery System
The crane’s 24V system is powered by two 12V batteries
connected in series (Figure 7-1
).
Always refer to wiring diagram for correct connections. Be
careful not to reverse the battery connections. Installing
batteries with reversed electrical connections will not only
damage batteries but also the crane’s electrical system,
voltage regulator, and/or alternator.
Maintenance
Checking Battery State-of-Charge
Special equipment is required to properly determine the
condition of a battery that has been in service. However, a
voltmeter can be used to determine a battery’s state-of-
charge by checking the voltage between the battery
terminals (Figure 7-2
) (Table 7-2).
This open-circuit test is the simplest test but not as accurate
in determining a battery’s condition as a hydrometer test.
The advantage is that the cell covers do not need to be
opened, eliminating the possibility of cell contamination and
electrolyte spill.
NOTE Do not use this test method if the battery has been
recently charged by a charger or alternator. Recent
charging places a high surface charge voltage
which is not a true indication of actual battery
voltage.
Table 7-2. Open Circuit Voltage
Consult the manual provided with the test meter for detailed
test information.
FIGURE 7-1
5
1
4
Item Description
1Battery Box Cover
2 Battery Mount Clamp
3Battery
4 Fuel Tank
5 Positive Terminal
6 Negative Terminal
7 Rubber Insulating Strip (10)
2
3
7
6
M100012
M100011
WARNING
Personal Injury Hazard
Each battery weighs 59 lbs (27 kg). Use proper lifting
procedures.
State-of-Charge Specific Gravity
Approximate
Open-Circuit
Voltage
(24V System)
100% 1.260 25.2
75% 1.230 24.8
50% 1.200 24.4
25% 1.170 24.0
0% 1.110 23.6
1
1
2
Item Description
1 Test Leads on Battery Terminals
2 Voltmeter
FIGURE 7-2
P1616

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals