Reference Only
ELECTRIC SYSTEM 14000 SERVICE MANUAL
3-14
Published 09-05-14, Control # 226-02
Node 4—Drum 4, Pumps, and Accessories
See Electrical Schematic A17144, Sheets 10, 17 and 18 (at end of this section).
Receptacle
Number
Function
Type
Description Test Voltages
CAN Packet
Number
J7-WN14
I/O Cable — From Node 4 to Engine Node N/A
J1-WN08
I/O Cable — From Node 4 to Node 3 N/A
J3/W43 Receptacle - Drum 2 and Pressure Senders
43-A Ground
Rigging Winch - Retract/Pay Out Ground
43-B DO-1
Rigging Winch - Retract 0 Volts Off; 24 Volts On CAN23-1-1
43-C Ground
Carbody Enable Pressure Sender Ground
43-D DO-2
Rigging Winch - Pay Out 0 Volts Off; 24 Volts On CAN23-1-2
43-E Ground
Swing/Travel Alarm/Jumper to Node Select 3 Ground
43-F DO-3
Drum 2 Motor Control See Table 3-2 for Values CAN23-1-4
43-G Ground
Drum 2 Pressure Sender Ground
43-H DO-4
Drum 2 Brake Release 0 Volts Off; 24 Volts On CAN23-1-8
43-J Ground
Engine Fuel Level Sensor Ground
43-M NS-3
Node Select 3 Jumper to Ground 0 Volts (With Jumper)
43-N Ground
Rigging Winch Brake Ground
43-P DO-6
Right Side Swing/Travel Alarm 0 Volts Off; 24 Volts On CAN23-1-32
43-R DO-5
Rigging Winch Brake 0 Volts Off; 24 Volts On CAN23-1-16
43-U 24 Volts
Drum 2 Pressure Sender 24 Volts Nominal
43-V 24 Volts
Engine Fuel Level Sensor 24 Volts Nominal
43-X 24 Volts
Carbody Enable Pressure Sender 24 Volts Nominal
43-Z 24 Volts
Swing Left Pressure Sender 24 Volts Nominal
43-c AI-3
Drum 2 Pressure Sender
1 Volt at 0 psi,
5 Volts at 7,000 psi
CAN12-6
1
43-d AI-4
Engine Fuel Level Sensor
1.8 Volts Full; 4.1 Volts
Empty
CAN12-8
1
43-e AI-5
Carbody Enable Pressure Sender
1 Volt at 0 psi,
5 Volts at 7,000 psi
CAN13-2
1
43-f AI-6
Swing Left Pressure Sender
1 Volt at 0 psi,
5 Volts at 7,000 psi
CAN13-4
1
43-g Ground
Swing Left Pressure Sender Ground
43-h Ground
Drum 2 Motor Control/Brake Release Ground
43-k Ground
Swing Right Pressure Sender Ground
43-m Ground
Drum 4 Pressure Sender Ground
43-n 24 Volts
Swing Right Pressure Sender 24 Volts Nominal
43-p AI-7
Swing Right Pressure Sender
1 Volt at 0 psi,
5 Volts at 7,000 psi
CAN13-6
1
43-r AI-8
Drum 4 Pressure Sender
1 Volt at 0 psi,
5 Volts at 7,000 psi
CAN13-8
1
43-s 24 Volts
Drum 4 Pressure Sender 24 Volts Nominal
J4/W44 Receptacle – Drum 4, and Pump Controls
44-A Ground
Drum 4/Pump 4 Ground
44-B DO-11
Drum 4 - Pump 4 0 Volts Off; 24 Volts On CAN23-2-4

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals