Manitowoc Published 09-05-14, Control # 226-02 10-15
14000 SERVICE MANUAL TROUBLESHOOTING
10
PROBLEM 14
Boom will not boom up, but will boom down.
POSSIBLE CAUSES
Boom maximum up limit opened; Pump is damaged;
Equalizer/boom stop limit opened; Control handle is worn.
CHECKS
When applicable switch or handle is enabled is the following displayed:
Maximum boom up limit fault.
Boom hoist pump pressure - raise, no increase in system pressure.
When moving boom hoist handle fully back, does Diagnostic screen
show 100% handle command in raise direction?
Check for problem. Repair limit
switch, wiring, or circuit breaker.
Yes No
Yes No
Yes No
Yes No
Does Diagnostic screen read 100% pump control with handle moved back?
Replace control handle.
Is 24 volts present (full speed) at pump EDC when control
handle is moved back?
(See Section 3 - Checking Electrical Inputs/Outputs.)
Consult dealer/factory.
Does pump charge pressure at charge pressure port drop to
247 psi (17 bar) or less when booming up?
Repair or replace wiring or consult dealer/factory.
Replace pump EDC.Repair or replace pump.
Any of the above displayed
None of the above displayed

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals