14000 SERVICE MANUAL TROUBLESHOOTING
10
CHECKS
Check for damage to pawl linkage. Check for pawl or pawl actuator/
cylinder for freedom of movement.
POSSIBLE CAUSES
Mechanical hang-up; No hydraulic pressure; No voltage to pawl solenoid;
Bad wiring; Actuator/cylinder failure.
No Damage
Drum 3 pawl in.
Drum 3 pawl out.
Boom hoist pawl in.
Boom hoist pawl out.
Damage
Repair damage. Test and adjust.
Move park brake switch to apply and release positions. Check drum Diagnostic screen
for pawl in and pawl out positions when applicable function was enabled:
If pawl is not moving
Is there voltage applied to pawl valve?
(See Section 3 -Checking Electrical Inputs/Outputs.)
Yes No
Check wiring. Consult dealer/factory.
When enabling problem pawl switch, check pawl cylinder for
350 psi (24 bar) or more at valve cylinder ports.
Pressure
No Pressure
Check for binding or
faulty cylinder.
Repair or replace
control valve.
Readjust source charge pressure relief
valve. Does this solve problem?
Repair or replace pump. Consult factory.
No
PROBLEM 22
Drum pawl is not operating correctly.

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals