EasyManuals Logo
Home>Mindray>Diagnostic Equipment>ME7

Mindray ME7 User Manual

Mindray ME7
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
4 Setup
Operator’s Manual 4 - 31
4.7 DICOM/HL7
4.7.1 DICOM Local Preset
TIP:
AE Title should be the same with the SCU AE Title preset in the server (PACS/RIS/HIS), for
example, if the AE Title of the server preset in the storage server is Storage, and the AE Title of
the accepted SCU is preset as Machine, then in the figure above, the AE Title of Local should
be Machine, and the AE Title of storage server should be Storage.
The device name is random. If the server name is same with that in the DICOM server list, the
information “the server added already exits”, click [OK] to retype the name.
IP address should be the address of the remote server.
DICOM local preset items are described as follows:
Item Description
Local Host
DICOM
service
property
AE Title Application Entity title.
Port Communication port, DICOM communication port.
PDU Maximum PDU data package size (not need to change),
ranging from 16384 to 65536; if the value is less than
16384 or greater than 65536, the system automatically
sets it to the value 32768.
DICOM output
charasets
Select an character set for DICOM output according to
the local PACS workstation.
Transcoding elements Set what DICOM element(s) will be transcoded.
TLS Port Set the TLS port.
TLS Server Setting Import the encryption key/certificate.
TLS Client Setting After importing TLS certificates, and selecting Verify
Certificate check box, the system verifies the
effectiveness of the TLS function in the DICOM
storage, print, and worklist services.
Import trusted certificates, or delete certificates.
Server Setting Device Name of the device supporting DICOM services.
IP Address IP address of the server.
Ping You can ping the other machines after you entered the
correct IP address.
Besides, you can select a server in the Device list to ping
it.
Device List Displays the added device.
Set DICOM Service Provides server settings of DICOM service, for details,
please refer to the following chapters.
Set DICOM Strategy Click to enter the configure the strategy screen.
Log Level For engineer use only.
Capture

Table of Contents

Other manuals for Mindray ME7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray ME7 and is the answer not in the manual?

Mindray ME7 Specifications

General IconGeneral
BrandMindray
ModelME7
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals