PARAMETERS
130
Pr. 52 "PU main display data
selection"
Related parameter
4.2.34 Actual operation hour meter clear (Pr. 171)
Pr. 171 "actual operation hour meter
clear"
You can clear the actual operation hour of the monitoring function.
Parameter
Number
Factory
Setting
Setting
Range
171 0 0
<Setting>
Write "0" in the parameter to clear the actual operation hour.
Pr. 173 to Pr. 176
#
##
#
Refer to Pr. 160.
4.2.35 Input terminal (remote output) function selection
(Pr. 180 to Pr. 183)
Pr. 180 "
(
RY4
)
function selection"
Pr. 181 "
(
RY3
)
function selection"
Pr. 182 "
(
RY2
)
function selection"
Pr. 183 "MRS terminal
(
RY9
)
function selection"
Use these parameters to select/change the input terminal functions.
Parameter
Number
Terminal
(Remote Output)
Symbol
Factory
Setting
Factory-Set Terminal
Function
Setting Range
180 (RY4) 0
Low-speed operation
command (RL)
0 to 3, 6, 8, 18
181 (RY3) 1
Middle-speed operation
command (RM)
0 to 3, 6, 8, 18
182 (RY2) 2
High-speed operation
command (RH)
0 to 3, 6, 8, 18
183 MRS(RY9) 6 Output shut-off (MRS) 0 to 3, 6 to 8, 18