2202L5JE-DA-C5-N_2015.05.
Important Information
Compound 2-stage Screw Compressor 1612LSC Speed Increaser Type
iii
Important Information
Intended Use of this Product
This product is a general-purpose screw compressor intended for refrigeration and cold storage.
Do not use the product for any purposes for which it was not intended or which depart from the
specifications. For specifications of this product, refer to “2.3 Compressor Specifications”.
The maintenance items described in this manual should be performed safely and closely following
procedures.
Important Information for Safe Use of this Product
Although MAYEKAWA has thoroughly considered the safety measures for this product, all hazards,
including potential hazards caused by human error or environmental conditions, cannot be anticipated.
There are many guidelines that must be observed for operating this product. However, the warnings in
this manual and the safety labels on the product are not all inclusive. When operating this product,
always pay extreme attention to general safety precautions as well as on items described in this
manual.
Important rules for safe operation that apply to all workers including managers and supervisors are
listed below.
Before using this product, carefully read and fully understand the contents written in this manual and
pay attention to safety.
Operation, maintenance, and inspection of this product should be performed by qualified
personnel educated about the fundamentals of the product and trained about the hazards
involved and measures to avoid danger.
Do not allow anyone other than those educated about the fundamental expertise of the
product and trained about hazards involved and measures to avoid dangers to approach the
product while it is operating or during maintenance.
Observe all related federal/national and local codes and regulations.
To prevent accidents, do not carry out any operation or maintenance other than those
described in this manual, or use the product for any unapproved purpose.
Replace parts with
genuine parts.
Not only workers but also managers should actively participate in safety and health activities in
the workplace to prevent accidents.
When closing or opening valves during work, apply lockout/tagout without failure, to prevent
the valves from closing or opening accidentally during the work.
[Lockout] To lock with a key in order to keep people, except the workers involved, from
operating the product.
“Lockout” means disconnecting or keeping disconnected machines and devices by locking their energy
(power) sources. Lockout is not just simply turning off the power switches to stop the supply of power,
but includes immobilizing them with a key or similar device to keep any blocked switches from being
operated.
Lockout devices are devices such as keys, covers, and latches, to immobilize switches, valves,
opening and closing levers, etc., with a state of being locked.
[Tagout] To prevent any inappropriate work by hanging tag plates indicating “work in progress”.
“Tagout” means to clearly indicate, by hanging tag plates, that a device is in lockout and that operation
of the device is prohibited. Tag plates forbidding operation, starting, opening, etc. are warnings clearly
stating to not operate energy (power) sources, and are not for stopping blocking devices.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the mycom 1612LSC series and is the answer not in the manual?

mycom 1612LSC series Specifications

General IconGeneral
Brandmycom
Model1612LSC series
CategoryAir Compressor
LanguageEnglish

Related product manuals