General Routing Guidelines
PRELIMINARY INFORMATION
Jetson Orin NX Series and Jetson Orin Nano Series DG-10931-001_v1.1 | 84
17.5 Common High-Speed Interface
Requirements
The following table describes the common high-speed interface requirements.
Table 17-2. Common High-Speed Interface Requirements
Parameter
Requirement
Units
Notes
Common-mode Choke (Not recommended only used if absolutely required for EMI issues)
Preferred device
Type: TDK ACM2012D-900-2P. Only if
needed. Place near connector. Refer to
Common Mode Choke Requirement
section.
Location - Max distance from to adjacent
discontinuities ex, connector, AC cap)
8 (53)
mm (ps)
TDK ACM2012D-900-2P
See Figure 17-2
@TR-200ps (10%-90%)
Common-mode impedance @ 100MHz Min/Max
65/90
Max Rdc
0.3
Differential TDR impedance
90
Min Sdd21 @ 2.5GHz
2.22
dB
Max Scc21 @ 2.5GHz
19.2
dB
Serpentine
Min bend angle
135
S1 must be taken care to consider Xtalk
to adjacent pair. See USB 3.2 Guideline
in Figure 17-3.
Dimension Min A Spacing
Min B, C Length
Min Jog Width
4x
1.5x
3x
Trace width
General
Routing over Voids
Routing over voids not allowed except void around device ball/pin the signal
is routed to.
Noise Coupling
Keep critical high-speed traces away from other signal traces or unrelated
power traces and areas or power supply components
The following figures show the common high-speed interface signal routing requirements.
Figure 17-2. Common Mode Choke

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nvidia Jetson Orin NX Series and is the answer not in the manual?

Nvidia Jetson Orin NX Series Specifications

General IconGeneral
BrandNvidia
ModelJetson Orin NX Series
CategoryControl Unit
LanguageEnglish

Related product manuals