BA_OTE 3+4_Endkunde_EN_V03_20170726.docx Page 19 of 52
5.14 Set temperature for cooling
- Any change in the room temperature set value will automatically shift the cooling
curve and change the cooling limit (the cooling curve is related to a room tempera-
ture set value of 22°C).
- Every heating circuit can also cool, provided it was parametered during commis-
sioning.
Set values Description
03-054 Room temp day cooling
operation
The desired normal room temperature is set here.
(see time program)
03-056 Room temp night cooling
operation
The desired set-back room temperature is set here.
(see time program)
Settings procedure:
1. Press the adjustment knob in the main
display > the main menu appears
2. Select the Heating Circuit by turning the
adjustment knob and confirm by pressing
the knob. > the temperature image for the
heating circuit appears.
3. In heating circuit temperature image, se-
lect the heating circuit menu by pressing
the adjustment knob.
4. By turning the adjustment knob, select
settings in the main menu and confirm this
by pressing the knob.
5. By turning the adjustment knob, select
target temperature cooling and confirm
this by pressing the knob.
6. Select the Room temp. day cooling opera-
tion by pressing the adjustment knob
7. Change/adjust the room temperature by
turning the adjustment knob and store this
by pressing. > By repeated pressing of the
ESC – knob you return to the main display.
Target temperature heating
Target temperature cooling