EasyManuals Logo
Home>Ochsner>Control Unit>OTE 3

Ochsner OTE 3 User Manual

Ochsner OTE 3
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
BA_OTE 3+4_Endkunde_EN_V03_20170726.docx Page 19 of 52
5.14 Set temperature for cooling
- Any change in the room temperature set value will automatically shift the cooling
curve and change the cooling limit (the cooling curve is related to a room tempera-
ture set value of 22°C).
- Every heating circuit can also cool, provided it was parametered during commis-
sioning.
Set values Description
03-054 Room temp day cooling
operation
The desired normal room temperature is set here.
(see time program)
03-056 Room temp night cooling
operation
The desired set-back room temperature is set here.
(see time program)
Settings procedure:
1. Press the adjustment knob in the main
display > the main menu appears
2. Select the Heating Circuit by turning the
adjustment knob and confirm by pressing
the knob. > the temperature image for the
heating circuit appears.
3. In heating circuit temperature image, se-
lect the heating circuit menu by pressing
the adjustment knob.
4. By turning the adjustment knob, select
settings in the main menu and confirm this
by pressing the knob.
5. By turning the adjustment knob, select
target temperature cooling and confirm
this by pressing the knob.
6. Select the Room temp. day cooling opera-
tion by pressing the adjustment knob
7. Change/adjust the room temperature by
turning the adjustment knob and store this
by pressing. > By repeated pressing of the
ESC knob you return to the main display.
NOTES:
HEATING CIRCUIT 1
ESC
MENU
03-054
HEATING CIRCUIT 1
Room temp day
cooling operation
22.0 °C
ESC
03-054
HEATING CIRCUIT 1
Room temp day
cooling operation
22.0 °C
ESC
HEATING CIRCUIT 1
03-054
Room temp day
22.0
Room temp night
25.0
Slope summer co
20
Start point sum
28.0
ESC
ENTER
03-056
03-045
03-044
HEATING CIRCUIT 1
Time programm
ESC
ENTER
Target temperature heating
Heating curve
Target temperature cooling
HEATING CIRCUIT 1
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
Heating mode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
2
1
7
6
4
6
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ochsner OTE 3 and is the answer not in the manual?

Ochsner OTE 3 Specifications

General IconGeneral
BrandOchsner
ModelOTE 3
CategoryControl Unit
LanguageEnglish