6 Hot water circuit
Hot water heating has priority over heating/cooling. During hot water heating - depend-
ing on the type of system/control setting - the heating circuit pumps are switched off.
6.1 Operation selection
The following modes of operation can be set:
Operation selection Description
0: No charging
No hot water charging
the frost protection temperature
for hot water (10°C) is active.
1: Automatic
The hot water charging takes place via the time program for
hot water/anti-legionella function
2: Normal daytime tem-
perature
Hot water charging always takes place according to the
standard temperature (no consideration of the time pro-
gram).
Settings procedure:
1. Press the adjustment knob in the main
display > the main menu appears
2. Select the Hot Water Circuit by turning the
adjustment knob and confirm by pressing
the knob. > the temperature image for the
hot water circuit appears.
3. In hot water circuit temperature image,
select the hot water circuit menu by press-
ing the adjustment knob.
4. By turning the adjustment knob, select
Operation mode in the hot water menu
and confirm this by pressing the knob.
5. Change/adjust the operation selection by
turning the adjustment knob and store this
by pressing.
05-050
HOT WATER
Operation mode
domestic hot water
1: Automatic
ESC
HOT WATER
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
ESC
MENU
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
Heating mode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
1
2
3
4
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ochsner OTE 3 and is the answer not in the manual?

Ochsner OTE 3 Specifications

General IconGeneral
BrandOchsner
ModelOTE 3
CategoryControl Unit
LanguageEnglish