EasyManuals Logo
Home>Ochsner>Control Unit>OTE 3

Ochsner OTE 3 User Manual

Ochsner OTE 3
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
BA_OTE 3+4_Endkunde_EN_V03_20170726.docx Page 43 of 52
16.3 ERROR
The ERROR report appears when the heat pump is switched off via a safety device / safe-
ty function. In ERROR cases, the system changes to "emergency operation - reduced". The
system is controlled at reduced temperatures (heating and warm water) and the addi-
tional heat generators (electro auxiliary, furnace) take over the heating (if installed).
Emergency mode economy: The set value for heating will be reduced by 7°C; the set val-
ue for hot water to 35°C.
NOTE
The heat pump restarts automatically when the safety device releases the heat pump (er-
ror no longer in system).
Following malfunction repair measures are possible:
2 Automatic acknowledgement
3 Manual acknowledgement
The manual acknowledgement only leads to a heat pump restart when the error is no
longer present at the safety device.
16.4 Procedure by ERROR
Contact your contractual partner and try to acknowledge the error. If the error is no long-
er present after acknowledgement, the heat pump restarts and the additional heat gen-
erators turn off.
Example of error acknowledgement:
1. Press the ESC knob in the main display >
the error menu appears.
2. The error number as well as the error are
displayed in the error menu. The error can
be acknowledged by pressing the settings
knob > repeated pressing of the ESC knob
returns to main display.
Remedying the ERROR reports may only be carried out by OCHSNER authorised
installers! Before beginning work on the heat pump, it must be switched off on
all poles from the power supply and protected against switching back on! Incor-
rect changes to settings by third parties will delete all warranty and guarantee
claims.
>Phase error/rotation
>Check EVU sw itch
ESC
Aknowledge
Er 30: Phase monitoring
Starting current limiter
Sa 20.07.2013
15:41
ERROR
Emergency mode economy
MENU
INFO
2
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ochsner OTE 3 and is the answer not in the manual?

Ochsner OTE 3 Specifications

General IconGeneral
BrandOchsner
ModelOTE 3
CategoryControl Unit
LanguageEnglish