6.5 Set hot water temperature
3 set temperatures can be set for each hot water circuit.
Set values Description
05-051 Normal setpoint DHW temperature
The desired hot water temperature is set
here.
05-004 Legionella protection temperature
The legionella protection temperature is
set here.
05-086 Economy setpoint DHW temperature
The hot water set-back temperature is set
here.
Settings procedure:
1. Press the adjustment knob in the main
display > the main menu appears
2. Select the Hot water circuit in the main
menu
3. In hot water circuit temperature image,
select the hot water circuit menu by
pressing the adjustment knob.
4. By turning the adjustment knob, select
settings in the main menu and confirm
this by pressing the knob.
5. Select Setpoint and confirm by pressing
the adjustment knob
6. Select Normal setpoint DHW temperature
by pressing the settings knob and cali-
brate.
7. Change/adjust the parameter by turning
the adjustment knob and store this by
pressing. By repeated pressing of the ESC
knob you return to the main display.
05-051
HOT WATER
Normal setpoint DHW
temperature
50.0 °C
ESC
ESC
ENTER
05-086
Economy setpoin
10
HOT WATER
05-051
Normal setpoint
50.0
05-004
Legionella prot
60.0
HOT WATER
Time programm
Setpoint
Configuration
ESC
ENTER
HOT WATER
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
ESC
MENU
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
Heating mode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
1
2
3
4
7
5
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ochsner OTE 3 and is the answer not in the manual?

Ochsner OTE 3 Specifications

General IconGeneral
BrandOchsner
ModelOTE 3
CategoryControl Unit
LanguageEnglish