4. REPLACEMENT OF PARTS
4.2.7 Main controller PCB, image drum motor, image
drum lift-up motor and feed motor
(1) Open the top cover.
(2) Remove the right side cover (see section 4.2.4).
(3) Remove the ten screws (silver-colored)
and the plate shield Assy. (tool
number 1).
(4) Remove the FFC cables
of the LED heads, the RFID FFC cable and the
power supply connector .
C