9 - 7
9 Setting Up Slave Terminals
NX-series EtherNet/IP Coupler Unit User’s Manual (W536)
9-2 Setting Slave Terminal
Parameters
9
9-2-1 Items to Set
9-2 Setting Slave Terminal Parameters
This section describes how to set the Slave Terminal parameters with Support Software. The Sysmac
Studio is used as an example.
For Support Software other than the Sysmac Studio, refer to the operation manual for the Support Soft-
ware that you are using.
The following settings must be adjusted in the Slave Terminal.
Specify the NX Unit configuration information for the Slave Terminal, which consists of an EtherNet/IP
Coupler Unit and NX Units.
EtherNet/IP Coupler Unit
The EtherNet/IP Coupler Unit settings are listed below.
You can set only the items that have “Yes” in the Settable column.
9-2-1 Items to Set
Name Description
Configura-
tion infor-
mation
Slave Terminal
configuration
information
This information describes the configuration of the Slave Terminal: the number
and order of NX Units mounted after the EtherNet/IP Coupler Unit, individual NX
Unit information, and information about the EtherNet/IP Coupler Unit.
I/O allocation
information
This information defines the I/O data in the EtherNet/IP Coupler Unit and the NX
Units.
Slave Terminal operation set-
tings
The Slave Terminal operation settings are for the EtherNet/IP Coupler Unit and
the NX Units.
NX Unit application data This data controls the functionality that is specific to each NX Unit. Not all NX
Units have Unit application data.
9-2-2 Setting the NX Unit Configuration Information
Settings in the NX Unit Configuration Information
NX Units
NX Unit configuration information
EtherNet/IP
Coupler Unit