9 Setting Up Slave Terminals
9 - 16
NX-series EtherNet/IP Coupler Unit User’s Manual (W536)
NX Unit Message Enabled Status
NX Unit I/O Data Active Status
Data name Description
NX Unit Message Enabled
Status 15
This status tells whether the NX Units can process message communications.
The status is acquired for as many NX Units as the numeric suffix at the end of
the data name. Select the I/O data with the appropriate numeric value based on
the number of NX Units that are mounted.
This status is given as an array of BOOL data. The subscript of the array corre-
sponds to the NX Unit number. A subscript of 0 indicates the EtherNet/IP Coupler
Unit.
Each bit has the following meaning.
TRUE: Message communications possible.
FALSE: Message communications not possible.
The status says that message communications are enabled for NX Units that
meet the following conditions.
• The comparison shows no differences (only if the Unit configuration information
is registered).
• The NX Unit does not have a WDT error.
The status is FALSE for NX Units that are set as unmounted Units.
Each bit is updated when the message communications status changes on the
corresponding NX Unit.
NX Unit Message Enabled
Status 31
NX Unit Message Enabled
Status 63
Data name Description
NX Unit I/O Data Active Sta-
tus 15
This status tells whether the NX Units can process I/O data communications.
The status is acquired for as many NX Units as the numeric suffix at the end of
the data name. Select the I/O data with the appropriate numeric value based on
the number of NX Units that are mounted.
This status is given as an array of BOOL data. The subscript of the array corre-
sponds to the NX Unit number. A subscript of 0 indicates the EtherNet/IP Coupler
Unit.
Each bit has the following meaning.
TRUE: The I/O data in the NX Unit can be used for control.
FALSE: The I/O data in the NX Unit cannot be used for control.
The status is FALSE for NX Units that are set as unmounted Units.
Each bit is updated when the operating status changes on the corresponding NX
Unit.
NX Unit I/O Data Active Sta-
tus 31
NX Unit I/O Data Active Sta-
tus 63