6 - 25
6 Parameters
E5@C-T Digital Temperature Controllers User’s Manual (H185)
6-5 Adjustment Level
6
M
1234
l.adj
M
off
at
M
off
cmwt
M
psp
spmd
M
Fixed SP
0
fsp
M
0.0
ct1
M
0.0
hb1
M
0.0
ct2
M
0.0
hb2
M
0.0
lcr1
M
50.0
hs1
M
0.0
lcr2
50.0
hs2
M
0.0
ins
M
1.000
inrt
Standby Time
M
0.00
Rstb
Program SP
Shift Value
M
0
Rpsps
M
8.0
p
M
233
i
M
40
d
M
8.0
c-p
M
M
233
c-i
50.0
of-r
M
1.0
hys
M
M
off
wt-b
MV at Reset
M
0.0
mv-r
0.0
mv-e
M
M
100.0
ol-h
M
0.0
ol-l
M
0.0
sqrp
M
0.8
oc-h
M
0.0
orl
2.0
db
M
M
w2on
M
w3on
w4on
M
w5on
M
w6on
M
w7on
M
w8on
M
w1of
M
w2of
M
w3of
M
w4of
M
M
w5of
w6of
M
w7of
M
M
w8of
plcm
40
c-d
0.0
c-db
M
M
M
w1on
M
M
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1.0
chys
SP Mode
PV Input Shift
PV Slope
Coefficient
Proportional
Band (Cooling)
Integral Time
(Cooling)
Work Bit 1 OFF
Delay
Work Bit 1 ON
Delay
Derivative Time
(Cooling)
Work Bit 2 ON
Delay
Adjustment Level
Page
Adjustment
Level Display
AT Execute/
Cancel
Communications
Writing
Heater Current 1
Value Monitor
Heater Current 2
Value Monitor
Heater Burnout
Detection 1
Heater Burnout
Detection 2
HS Alarm 1
HS Alarm 2
Proportional
Band
Integral Time
Derivative Time
Dead Band
Manual
Reset Value
Hysteresis
(Heating)
Hysteresis
(Cooling)
Wait Band
MV at PV Error
MV Upper Limit
MV Lower Limit
MV Change
Rate Limit
Page
Page
Page
Extraction of
Square Root
Low-cut Point
Work Bit 2 OFF
Delay
Work Bit 3 ON
Delay
Work Bit 3 OFF
Delay
Work Bit 4 ON
Delay
Work Bit 4 OFF
Delay
Work Bit 5 ON
Delay
Work Bit 5 OFF
Delay
Work Bit 6 ON
Delay
Work Bit 6 OFF
Delay
Work Bit 7 ON
Delay
Work Bit 7 OFF
Delay
Work Bit 8 ON
Delay
Work Bit 8 OFF
Delay
Position
Proportional
Dead Band
Open/Close
Hysteresis
Communications
Monitor
Leakage
Current 1 Value
Monitor
Leakage
Current 2 Value
Monitor
6-26
6-27
6-28
6-28
6-29
6-30
6-30
6-31
6-31
6-32
6-32
6-33
6-33
6-33
6-36
6-36
6-36
6-37
6-37
6-37
6-37
6-38
6-38
6-39
6-40
6-40
6-41
6-41
6-42
6-43
6-43
6-43
6-43
6-38
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-43
6-34
6-42
6-29
6-34
6-35
6-39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5AC-T and is the answer not in the manual?

Omron E5AC-T Specifications

General IconGeneral
BrandOmron
ModelE5AC-T
CategoryTemperature Controller
LanguageEnglish

Related product manuals