A Appendices
A - 26
E5@C-T Digital Temperature Controllers User’s Manual (H185)
*1
*1.1 Initialized when the transfer output type is changed.
Initialized if the input type, temperature unit, scaling upper/lower limit, or SP upper/lower limit is changed
when the transfer output type is SP or PV.
(When initialized by the initializing settings, it is initialized to 100.0/0.0.)
*2 This function can be set for heating/cooling control or for floating control for Position-proportional Models,
but the setting will be disabled.
*1 When the Manual MV Limit Enable parameter is set to ON, the setting range will be the MV lower limit to the MV upper
limit.
*2 The valve opening is monitored for floating control or for close control with the Direct Setting of Position-proportional MV
parameter set to OFF.
The contents displayed vary depending on the Monitor/Setting 1 to 5 (advanced function setting
level) setting.
Event Input
Assignment 5
ev-5 Same as Event Input Assignment 1. Same as
Event Input
Assignment 1.
NONE None
Event Input
Assignment 6
ev-6 Same as Event Input Assignment 1. Same as
Event Input
Assignment 1.
NONE None
Close/Floating clfl FLOT: Floating control
CLOS: Close control
flot, clos FLOT None
Motor Calibration calb OFF or ON off, on OFF None
Trave l Time mot 1 to 999 30 Seconds
Valve Completely
Closed Position
vl-c 0 to 9,999 0 None
Valve Completely
Open Position
vl-o 0 to 9,999 9999 None
Potentiometer
Specification Setting
pms 0 to 5 0 None
Extraction of Square
Root Enable
sqr OFF: ON off, on OFF(0) None
Move to Advanced
function Setting Level
amov −1,999 to 9,999 0 None
Transfer output type Setting (monitor) range
Default*1.1
(transfer output upper/lower
limits)
Unit
Present SP SP lower limit to SP upper limit SP upper limit/lower limit EU
PV Temperature input: Input setting range lower
limit to Input setting range upper limit
Input setting range upper/lower
limit
EU
Analog input: Scaling lower limit to Scaling
upper limit
Scaling upper/lower limit
MV (Heating) Standard: −5.0 to 105.0
Heating/cooling: 0.0 to 105.0
100.0/0.0 %
MV (Cooling) 0.0 to 105.0 100.0/0.0 %
Valve opening −10.0 to 110.0 100.0/0.0 %
A-6-6 Manual Control Level
Parameters Setting (monitor) value Default Unit
Manual MV
−5.0 to 105.0 (standard)
*1
−105.0 to 105.0 (heating/cooling)
*2
−5.0 to 105.0 (position-proportional)
*1*2
0.0 %
A-6-7 Monitor/Setting Item Level
Parameters Characters Setting (monitor) value Display Default Unit