E5@C-T Digital Temperature Controllers User’s Manual (H185)
A-6 Parameter Operation Lists
A
A-6-9 Protect Level
*1 If the Manual MV Limit Enable parameter is set to ON, the setting range will be the MV lower limit to the
MV upper limit.
*2 The setting ranges are different for relay and voltage outputs (for driving SSR) and for linear current
outputs.
*3 WR1 to WR8 are not displayed when the logic operation function is not used.
PV/SP No. 1 Display
Selection
spd1 0: Nothing is displayed.
1: PV/SP/Nothing displayed
2: PV/Nothing displayed/Nothing displayed
3: SP/SP (character display)/Nothing displayed
4: PV/SP/MV (heating) (valve opening for
Position-proportional Models)
5: PV/SP/MV monitor (cooling)
6: PV/SP/Program number and segment number
7: PV/SP/Remaining segment time
6 None
PV/SP No. 2 Display
Selection
spd2 Same as PV/SP No. 1 Display Selection. E5CC-T: 0,
E5EC-T/E5A
C-T: 7
None
PV Status Display
Function
pvst OFF: OFF
MANU: Manual
RST: Reset
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
STB: Standby
off
manu
rst
alm1
alm2
alm3
alm4
alm
ha
stb
OFF None
SV Status Display
Function
svst OFF: OFF
MANU: Manual
RST: Reset
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
STB: Standby
off
manu
rst
alm1
alm2
alm3
alm4
alm
ha
stb
OFF None
Display Refresh Period d.ref OFF, 0.25, 0.5, 1.0 off, 0.25,
0.5, 1.0
0.25 Second
Burnout Method burn Upscale or downscale up, down Upscale None
Parameter Mask
Settings
pmse OFF, ON off, on OFF None
Move to Calibration
Level
cmoV −1999 to 9999 0 None
A-6-9 Protect Level
Parameters Characters Setting (monitor) value Display Default Unit
Move to Protect level
pmoV −1999 to 9999 0 None
Operation/Adjustment Protect oapt 0 to 5 0 None
Initial Setting/Communications Protect icpt 0 to 2 1 None
Setting Change Protect wtpt OFF, ON off, on OFF None
PF Key Protect pfpt OFF, ON off, on OFF None
Parameter Mask Enable
pmsk OFF, ON off, on ON None
Password to Move to Protect Level
prlp −1,999 to 9,999 0 None
Parameters Characters Setting (monitor) value Display Default Unit