12 - 15
12 Troubleshooting and Maintenance
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
12-4 Troubleshooting
12
12-4-1 Troubleshooting with Error Displays
14 hex 0 hex Overcurrent The current flowing through the converter
exceeded the specified value.
• The Servo Drive is faulty (faulty circuit,
faulty IGBT part, etc.).
• Disconnect the motor cable, and turn
ON the servo. If the problem
immediately recurs, replace the Servo
Drive with a new one.
• The motor cable is short-circuited
between phases U, V, and W.
• Check to see if the motor cable is
short-circuited between phases U, V and
W by checking for loose wire strands on
the connector lead. Connect the motor
cable correctly.
• The motor cable is ground-faulted. • Check the insulation resistance between
phases U, V, and W of the motor cable
and the grounding wire of the motor. If
the insulation is faulty, replace the motor.
• Motor windings are burned out. • Check the balance between the
resistance of each wire of the motor. If
resistance is unbalanced, replace the
motor.
1 hex IPM Error • The motor wiring contacts are faulty. • Check for missing connector pins in
motor connections U, V, and W. If any
loose or missing connector pins are
found, secure them firmly.
• The relay for the dynamic brake has
been welded due to frequent servo
ON/OFF operations.
• Replace the Servo Drive. Do not start or
stop the system by turning the servo ON
or OFF.
• The motor is not suitable for the Servo
Drive.
• Check model (capacity) of the motor and
the Servo Drive on the nameplates.
Replace the motor with a motor that
matches the Servo Drive.
• The command input timing is the same
as or earlier than the Servo ON timing.
• Wait at least 100 ms after the servo has
been turned ON, then input commands.
• The resistance of the connected
External Regeneration Resistor is less
than the minimum allowable value.
*1
• Connect an External Regeneration
Resistor whose resistance is more than
the minimum allowable value.
*2
15 hex 0 hex Servo Drive
Overheat
The temperature of the Servo Drive
radiator or power elements exceeded the
specified value.
• The ambient temperature of the Servo
Drive exceeded the specified value.
• Improve the ambient temperature and
the cooling conditions of the Servo
Drive.
• Overload • Increase the capacities of the Servo
Drive and the motor. Set longer
acceleration and deceleration times.
Reduce the load.
Error No.
Name Cause Measures
Main Sub

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN10F-ECT-L and is the answer not in the manual?

Omron R88D-KN10F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN10F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals