3 Specifications
3 - 2
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
3-1 Servo Drive Specifications
Select a Servo Drive that matches the Linear Motor to be used.
Note 1 The above items reflect individual evaluation testing. The results may differ under compound conditions.
2 Disconnect all connections to the Servo Drive before attempting a megameter test (insulation resistance
measurement) on a Servo Drive. Failure to follow this guideline may result in damaging the Servo Drive.
3 Never perform dielectric strength or other megameter tests on the Servo Drive. Failure to follow this guideline may
result in damaging the internal elements.
4 Some Servo Drive parts will require maintenance. For details, refer to 12-5 Periodic Maintenance on page 12-35.
5 Following may be caused by incoming electrical noise (unstable, vibration, accoustic noise, etc.). In such case, refer
to 4-4 Noise Reduction on page 4-29 for measure to reduce noise.
z International standard
*1 This Servo Drive is third-party certified in combination with rotary motor models. It is the user's responsibility to perform
final checks on the compliance of the entire system.
3-1-1 General Specifications
Item Specifications
Operating ambient
temperature and humidity
0 to 55°C, 20% to 85% max. (with no condensation)
Storage ambient
temperature and humidity
–20 to 65°C, 20% to 85% max. (with no condensation)
Operating and storage
atmosphere
No corrosive gases
Vibration resistance
10 to 60 Hz and at an acceleration of 5.88 m/s
2
or less (Not to be run continuously at a
resonance point)
Insulation resistance Between power supply terminals/power terminals and FG terminal: 0.5 MΩ min. (at 500 VDC)
Dielectric strength Between power supply/power terminals and FG terminal: 1,500 VAC for 1 min at 50/60 Hz
Protective structure Built into panel
EC Directives
*1
EMC Directive EN55011, EN61000-6-2, EN61800-3
Low Voltage
Directive
EN 61800-5-1
Machinery
Directives
EN954-1(Cat.3), EN ISO13849-1 (Cat.3)(PLc, d), ISO13849-1(Cat.3)(PLc, d),
EN61508(SIL2), EN62061(SIL2), EN61800-5-2 (STO), IEC61326-3-1 (SIL 2)
UL standards UL 508C
CSA standards CSA C22.2 No.14
Korean Radio Regulations (KC) Compliant