1074
Network Instructions Section 3-25
3-25-7 EXPLICIT GET ATTRIBUTE: EGATR(721)
Purpose Sends an information/status read command in an explicit message (Get
Attribute Single, Service Code: 0E hex).
This instruction is supported by only by CS/CJ-series CPU Unit Ver. 2.0 or
later.
Ladder Symbol
Variations
Applicable Program Areas
Operands S: First word of send message
Specifies the first word of the send message (S to S+3).
EGATR(721)
S
D
C
S: First word of send message
D: First word of received message
C: First control word
Variations Executed Each Cycle for ON Condition EGATR(721)
Executed Once for Upward Differentiation @EGATR(721)
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification Not supported
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK
S0 0
8
111215
0
7
S+1 0 0
8
111215
07
S+2 0 0
8
111215
07
S+3 0 0
8
111215
07
Class ID (hex)
Instance ID (hex)
Attribute ID (hex)
Destination Node Address
00 to max. node address (hex)
(00 to 3F hex (0 to 63) for DeviceNet)
If the Attribute ID is not used, set it
to FFFF hex. (The Attribute ID
cannot be set to 0000 hex.)