1176
Other Instructions Section 3-31
Note If there is no CS/CJ-series equivalent to the specified CV-series PLC memory
address, an error will occur, the Error Flag will be turned ON, and the address
will not be converted.
When an Index Register is used as an operand with a “,IR” prefix, the instruc-
tion will operate on the word indicated by the PLC memory address in the
Index Register, not the Index Register itself. Once the desired PLC memory
address has been stored in an Index Register, the Index Register itself can be
used as an operand for an instruction.
The FRMCV(284) instruction can be used to convert a CV-series program
with the following two kinds of programming for use in a CS/CJ-series PLC.
See the Examples later in this section for an example.
1. When using indirect binary mode DM addressing (*DM)
(when indirectly specifying a data area address with a PLC memory ad-
dress in DM)
2. When using CV-series PLC memory addresses directly as values
(when storing PLC memory addresses in Index Registers with direct ad-
dressing using an instruction such as MOV(021))
Operand Specifications
0000Hex
0001Hex
2000Hex
2001Hex
FFFDHex
0000CH
0001CH
D00000
D00001
E32765
0C000Hex
0C001Hex
10000Hex
10001Hex
FFFFFHex
0000CH
0001CH
D00000
D00001
EC_32767
S
IR1 10001Hex
D:
Specify the CV-series PLC
memory address in S. (In this
case, 2001 hex is the PLC
memory address of D00001.)
Data area address PLC memory address
Convert
Corresponding
data area
address
CV-series
The corresponding CS/CJ-series PLC
memory address is stored in D. (In this
case, data area address D00001 is
converted to PLC memory address
10001 hex and stored.)
Convert
CS/CJ-series
Area S D
CIO Area CIO 0000 to CIO 6143 ---
Work Area W000 to W511 ---
Holding Bit Area H000 to H511 ---
Auxiliary Bit Area A448 to A959 ---
Timer Area T0000 to T4095 ---
Counter Area C0000 to C4095 ---
DM Area D00000 to D32767 ---
EM Area without bank E00000 to E32767 ---
EM Area with bank En_00000 to En_32767
(n = 0 to C)
---

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 and is the answer not in the manual?

Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ - REFERENCE MANUAL 08-2008
CategoryController
LanguageEnglish

Related product manuals