953
Basic I/O Unit Instructions Section 3-23
Flags
Precautions Do not read or write the system word (C) from any other instruction. HKY(212)
will not operate correctly if the system word is accessed by another instruc-
tion. The system word is not initialized by HKY(212) in the first cycle when
program execution starts. If HKY(212) is being used from the first cycle, clear
the system word from the program.
HKY(212) will not operate correctly if I/O refreshing is not performed with the
Input Unit and Output Unit connected to the hexadecimal keypad after
HKY(212) is executed. Consequently, set the input time constant for the Input
Units used for the data line input word to a value that is shorter than the cycle
time, or do not connect the hexadecimal keypad to the following Units.
• Basic I/O Units or High-density I/O Units mounted in a SYSMAC BUS
Remote I/O Slave Rack
• Communications Slaves (DeviceNet or CompoBus/S Slaves)
Example In this example, HKY(212) reads up to 8 digits of hexadecimal data from a
hexadecimal keypad and stores the data in D00000 and D00001. The hexa-
decimal keypad is connected through CIO 0100 (allocated to a CS1W-ID211
16-point DC Input Unit) and CIO 0200 (allocated to a CS1W-OD211 16-point
Transistor Output Unit). D32000 is used as the system word.
3-23-8 MATRIX INPUT: MTR(213)
Purpose Inputs up to 64 signals from an 8 × 8 matrix connected to an Input Unit and an
Output Unit (using 8 input points and 8 output points) and stores that 64-bit
data in the 4 destination words.
This instruction is supported only by CS/CJ-series CPU Unit Ver. 2.0 or later.
Ladder Symbol
Variations
Applicable Program Areas
Name Label Operation
Error Flag ER OFF
I
O
D
C
HKY(212)
0100
0200
D00000
D32000
P_On
Always ON Flag
MTR(213)
I
O
D
C
I: Input word
O: Output word
D: First destination word
C: System word
Variations Executed Each Cycle for ON Condition MTR(213)
Executed Once for Upward Differentiation Not supported.
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification Not supported.
Block program areas Step program areas Subroutines Interrupt tasks
Not allowed OK OK Not allowed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 and is the answer not in the manual?

Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ - REFERENCE MANUAL 08-2008
CategoryController
LanguageEnglish

Related product manuals