735
Table Data Processing Instructions Section 3-17
3-17-12SUM: SUM(184)
Purpose Adds the bytes or words in the range and outputs the result to two words.
Ladder Symbol
Variations
Applicable Program Areas
C: D00100
C+1: D00101
R1:
D: D00300
R1
100CF
–2
–1
–3
1
000100CF
0
0
0
A
1: Treats data as signed binary.
1: Outputs address to IR00.
Always 0.
PC memory
address
Decimal
equivalent
Min. value
10 words
Number of words
SUM(184)
C
R1
D
C: First control word
R1: First word in range
D: First destination word
Variations Executed Each Cycle for ON Condition SUM(184)
Executed Once for Upward Differentiation @SUM(184)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification Not supported.
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK