309
Comparison Instructions Section 3-7
3-7-5 SIGNED BINARY COMPARE: CPS(114)
Purpose Compares two signed binary values (constants and/or the contents of speci-
fied words) and outputs the result to the Arithmetic Flags in the Auxiliary Area.
Ladder Symbol
Variations
Note Immediate refreshing is not supported by CS1D CPU Units.
Applicable Program Areas
Operand Specifications
(0)
(0)
(1)
>
=
<
Flag status
Result
Comparison
CPS(114)
S
1
S
2
S1: Comparison data 1
S
2: Comparison data 2
Variations Executed Each Cycle for ON Condition CPS(114)
Executed Once for Upward Differentiation Not supported
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification (See note.) !CPS(114)
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK
Area S
1
S
2
CIO Area CIO 0000 to CIO 6143
Work Area W000 to W511
Holding Bit Area H000 to H511
Auxiliary Bit Area A000 to A959
Timer Area T0000 to T4095
Counter Area C0000 to C4095
DM Area D00000 to D32767
EM Area without bank E00000 to E32767
EM Area with bank En_00000 to En_32767
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 and is the answer not in the manual?

Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ - REFERENCE MANUAL 08-2008
CategoryController
LanguageEnglish

Related product manuals