693
Double-precision Floating-point Instructions (CS1-H, CJ1-H, CJ1M, or CS1D Only) Section 3-16
Description PWRD(860) raises the double-precision (64-bit) floating-point number in
words B to B+3 to the power of the double-precision (64-bit) floating-point
number in words E to E+3. In other words, PWR(840) calculates X
Y
(X = con-
tent of B to B+3; Y = content of E to E+3).
For example, when the base words (B to B+3) contain 3.1 and the exponent
words (E to E+3) contain 3, the result is 3.1
3
or 29.791.
If the absolute value of the result is greater than the maximum value that can
be expressed as floating-point data, the Overflow Flag will turn ON.
If the absolute value of the result is less than the minimum value that can be
expressed as floating-point data, the Underflow Flag will turn ON.
Flags
EM Area with bank En_00000 to En_32764
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants ---
Data Registers ---
Index Registers ---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Area B E D
→
S1+1 S1S1+3 S1+2 D+1 DD+3 D+2
S2+1 S2S2+3 S2+2
Exponent data
Base data
Name Label Operation
Error Flag ER ON if the base data (B to B+3) or exponent data (E to
E+3) is not recognized as floating-point data.
ON if the base data (B to B+3) or exponent data (E to
E+3) is not a number (NaN).
ON if the base data (B to B+3) is 0 and the exponent data
(E to E+3) is less than 0. (Division by 0)
ON if the base data (B to B+3) is negative and the expo-
nent data (E to E+3) is non-integer. (Root of a negative
number)
OFF in all other cases.
Equals Flag = ON if both the exponent and mantissa of the result are 0.
OFF in all other cases.
Overflow Flag OF ON if the absolute value of the result is too large to be
expressed as a double-precision floating-point value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 and is the answer not in the manual?

Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ - REFERENCE MANUAL 08-2008
CategoryController
LanguageEnglish

Related product manuals