Operational controls
8 - 5
8.05.03 List of parameters
Group Parameter Explanation Adjustment range Standard value
1 116 No. of stitches for reduced 0 - 30 3
speed n1
117 Reduced speed n1 50 - 2250 1000
143 Reduced speed n3 1000 - 2700 2000
4 410 Alteration of speed n2 II
in steps of:
I = 10 RPM
II = 100 RPM
417 I = Display mode display II
machine unit counter
II = Display mode display
daily unit counter or n2
6 605 I = Actual RPM in the display II
II = No actual RPM in the
display
620 I = Countdown mechanism ON II
II = Countdown mechanism OFF
659 I = Normal running II
after fault correction
II = Reduced speed n3
after fault correction
7 718 Cycle brake 0 - 30 3
722 Acceleration ramp 1 - 50 44
723 Brake ramp 1 - 50 48
730 Lift delay for 0 - 250 100
work clamp
733 Language 1 - 6 ENGL
8 800 I = left running for sewing I
(Viewpoint Drive-BLM)
II = right running for sewing
884 P share speed regulation 1 - 50 10
In groups 2, 3 and 5 there are no parameters.
For further information see the Operation Manual of the motor.